Industrial Equipment

Operation, startup and types of failure of the most common equipment on the plant floor: pumps, compressors, motors, boilers and more.

9 articles

Boilers: energy savings and the maintenance plan, daily to annual

10 energy-saving measures for boilers and the maintenance tasks organized by their real frequency: daily, weekly, monthly and annual — what gets checked in each one, and why.

9 min read1 source

Burners and industrial furnaces: controlling combustion

The air purge before ignition, the flame detector that cuts the fuel, and the flue gas parameters that need watching — because in a burner, every efficiency checkpoint is also a safety checkpoint.

8 min read1 source

Centrifugal pumps: startup, key factors and types of failure

How to start and stop a centrifugal pump without damaging it, the four factors you always need to watch, and a way to classify its failures that helps diagnose them faster.

8 min read1 source

Compressors: lubrication, cooling and the preventive plan

Lubrication is the most important chapter in a compressor's life, and cooling decides a good part of its energy consumption. With the real preventive maintenance table for reciprocating compressors, by operating period.

7 min read1 source

Electric motors: efficiency rules, initial and major inspection

What the European efficiency regulation has required since 2015, the minimum insulation resistance values by power rating, and what gets checked at a motor's initial (500 h) and major (10,000 h) inspection.

9 min read1 source

Electrical substations: equipment to maintain and safety rules

What a substation is, the 19 systems that need maintaining, and the 5 golden rules for working on de-energized equipment — because in a substation, maintenance starts with safety, not the other way around.

8 min read1 source

Gas turbines: borescope inspection and acceptance criteria

How a gas turbine is inspected without opening the casing, the exact numerical limits that separate an acceptable defect from one that requires stopping the machine, and why its maintenance is almost always done by the manufacturer.

9 min read1 source

Natural gas engines: the hour-by-hour maintenance plan

From 50 to 48,000 hours of use: the staged preventive maintenance plan for a natural-gas reciprocating internal combustion engine, what gets checked at each stage, and the 6 systems where its typical failures originate.

9 min read1 source

Transformers: what degrades the insulation and how to inspect it

Moisture, oxygen, heat and external contamination are the four factors that degrade a transformer's insulation — with the table of which test to run on each component, from the windings to the radiators.

8 min read1 source